| Duomenų apsauga | 
|---|
| Palaikomi kanalai | 1 | 
| Suderinamumas su tinklu | 100Base-T (100Mbit), twisted pair 5, 5e, and 6 categories | 
| Įvesties jungtis (line side) | Jack RJ-45 | 
| Išvesties jungtis (device side) | Short cable with RJ-45 plug | 
| Įtampa DC (line-ground) UN | 175V DC | 
| Maksimali įtampa (line-ground) UC | 225V DC | 
| Apsaugos lygis 1kV/μs (line-ground) UP | 455V | 
| Viršįtampio srovė C1 (8/20µS, line-ground ) Iimp | 100A | 
| Įtampa DC (line-line) UN | 6V DC | 
| Maksimali įtampa (line-line) UC | 6,8V DC | 
| Apsaugos lygis 1kV/μs (line-line) UP C3 | 20V | 
| Viršįtampio srovė C1 (8/20µS, line-line ) Iimp | 100A | 
| Apsaugomos linijos | 1-2, 3-6 | 
| Talpa (line-line) @1MHz | 6-15pF | 
| Talpa (line-ground) @1MHz | 2-3pF | 
| Atsiejimas | Surge resistor | 
| Serijinis atsparumas | 2,2Ω / line | 
| Nominali srovė IN | 300mA / line | 
| PoE apsauga | 
|---|
| Įtampa DC (line-line) UN | 56V DC | 
| Maksimali įtampa(linia-linia) UC | 64V DC | 
| Apsaugos lygis UP C3 | 93V | 
| Viršįtampio srovė (8/20µS, line-line) Iimp C3 | 73A | 
| Apsaugomos poros | (1+2)-(3+6), (4+5)-(7+8) | 
| Saugomi PoE standartai 
 | IEEE 802.3af/at - all types | 
| Savybės | 
|---|
| Išmatavimai | 51 x 31 x 24 (mm) - without cable | 
| Pritaikymas | Insite / outside in additional IP66 housing | 
| Montavimas | Standalone | 
| IP apsaugos klasė | IP54 | 
| Veikimo temperatūra | -30ºC~60ºC |